Cookie policy: This site uses cookies (small files stored on your computer) to simplify and improve your experience of this website. Cookies are small text files stored on the device you are using to access this website. For more information on how we use and manage cookies please take a look at our privacy and cookie policies. Some parts of the site may not work properly if you choose not to accept cookies.

sections
 

schneider electric

Results 1 - 25 of 149Sort Results By: Published Date | Title | Company Name
Published By: Schneider Electric     Published Date: May 05, 2016
This paper proposes standard terminology for categorizing the types of prefabricated modular data centers, defines and compares their key attributes, and provides a framework for choosing the best approach(es) based on business requirements.
Tags : 
datacenters, tco, capacity, modular design, load, cost, architecture, networking
    
Schneider Electric
Published By: Schneider Electric     Published Date: May 05, 2016
This white paper provides a quantitative TCO analysis of the two architectures, and illustrates the key drivers of both the capex and opex savings of the improved architecture.
Tags : 
datacenters, tco, capacity, modular design, load, cost, architecture, networking
    
Schneider Electric
Published By: Schneider Electric     Published Date: May 05, 2016
In this paper, we focus on quantifying the capital cost differences of a prefabricated vs. traditional 440 kW data center, both built with the same power and cooling architecture, in order to highlight the key cost drivers, and to demonstrate that prefabrication does not come at a capex premium.
Tags : 
datacenters, tco, capacity, modular design, load, cost, architecture, networking
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 01, 2016
Earlier this year, Schneider Electric launched its preconfigured edge datacenter resources with its SmartBunker and SmartShelter products. In developing these products, Schneider closely examined the requirements for successful, secure, rapid edge deployments in support of the explosion of edge data. The result is a standardized solution that can be customized as required and deployed virtually anywhere.
Tags : 
data center, idc, schneider, iot schneider_uk
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 01, 2016
This paper discusses making realistic improvements to power, cooling, racks, physical security, monitoring, and lighting. The focus of this paper is on small server rooms and branch offices with up to 10kW of IT load.
Tags : 
schneider_uk, cooling, datacenter, networking
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 01, 2016
This white paper explains the drivers of edge computing and explores the various types of edge computing available.
Tags : 
edge schneider_uk, networking, security, data center
    
Schneider Electric
Published By: Schneider Electric     Published Date: Dec 09, 2016
Your business is ready for a new data center or an upgrade. But is your data center ready for your business? It can be. You want to optimize your ability to adapt to changing IT needs quickly while meeting performance and efficiency requirements. All while either deferring CapEx or reducing OpEx.
Tags : 
data center
    
Schneider Electric
Published By: Schneider Electric     Published Date: Aug 21, 2017
This white paper explains how micro data centers take advantage of existing infrastructure and demonstrates how this architecture reduces capital expenses by 42% over a traditional build.
Tags : 
edge computing, data center, micro data center, iot, bandwidt, data center, architecture
    
Schneider Electric
Published By: Schneider Electric     Published Date: Aug 21, 2017
A greater dependence on cloud-based applications means businesses must rethink the level of redundancy of the physical infrastructure equipment (power, cooling, networking) remaining on-premise, at the “Edge”.
Tags : 
cloud computing, private cloud, public cloud, storage infrastructure, hyperconvergence, data center
    
Schneider Electric
Published By: Schneider Electric     Published Date: Aug 21, 2017
This 12-page white paper describes what a data center reference design is, what it includes, and explains how the benefits listed above are achieved. A data center reference design acts as a starting point offering a project team several valuable benefits including: • Facilitating and simplifying the planning phase • Reducing time to create buildable designs • Reducing risk, offering predictable performance and improved reliability of the data center once operational
Tags : 
data center, design, reference design
    
Schneider Electric
Published By: Schneider Electric     Published Date: Aug 21, 2017
This paper explains how to specify the physical infrastructure for an IT pod and describes optimum configurations based on available power feeds, physical space, and targeted average rack power densities.
Tags : 
data centers, networking, architecture, it pod, infrastructure, data center
    
Schneider Electric
Published By: APC by Schneider Electric     Published Date: Apr 16, 2018
Power system operators have lots of questions about the aging switchgear they maintain: • How can we reduce risk for an outage or arc flash event? • What kind of project is required to fix my problems? • Is total replacement my best option? Find answers in "Answer Guide: Make Aging Switchgear Last Longer and Perform Better." Learn the benefits and how-tos of switchgear modernization and see easy-to-install solutions for any OEM's equipment.
Tags : 
switchgear modernization, mv circuit breakers, lv circuit breakers, switchgear upgrades, electrical distribution equipment, schneider electric, circuit breaker upgrade, obsolete switchgear
    
APC by Schneider Electric
Published By: APC by Schneider Electric     Published Date: Apr 16, 2018
"Institute of Electrical and Electronics Engineers (IEEE) standard 1584 has been the de facto standard for calculating the arc energy levels at different points in a power system. However, NFPA 70E provides the option of using the Arc Flash Hazard PPE Category task tables for PPE selection. Which is right for you, and what do you need to know about each option? Find answers in our white paper, which describes how both types of analysis systems work and how to be sure you are using the tables correctly."
Tags : 
arc flash, nfpa 70e compliance, ieee, electrical workplace safety, arc flash risk assessment, arc flash analysis, arc flash mitigation, solutions, ppe, tables, arc flash hazard, osha, electrical safety
    
APC by Schneider Electric
Published By: Modicon PLC     Published Date: Dec 04, 2012
Our repair technicians are capable of repairing most Modicon - Schneider Electric parts same day. Our exchange program allows us to send you a remanufactured unit while allowing you 30 days to return the failed unit for a credit.
Tags : 
    
Modicon PLC
Published By: APC by Schneider Electric     Published Date: Feb 09, 2011
In the broadening data center cost-saving and energy efficiency discussion, data center physical infrastructure preventive maintenance (PM) is sometimes neglected as an important tool for controlling TCO and downtime. PM is performed specifically to prevent faults from occurring. IT and facilities managers can improve systems uptime through a better understanding of PM best practices.
Tags : 
absolute, data protection, maitenance, ups, physical infrastructure, infrastructure, data loss protection, dlp, ponemon, it security, sensitive data
    
APC by Schneider Electric
Published By: Schneider Electric     Published Date: Feb 08, 2018
This paper contrasts the features of medium voltage fixed circuit breaker switchgear (FCBS) and existing withdrawable circuit breaker switgear (WCBS) designs. Modern FCBS design elements that are discussed include an internal disconnect for isolation and grounding of circuits and interlocked operation among disconnect, breaker, and grounding switch for improved safety. Furthermore, features such as lower maintenance, smaller footprint, and reduced life cycle costs that result from its simpler design will be explored. By comparing the traditional ANSI WCBS technology to that of the FCBS, this paper will demonstrate that the fixed design, which has gained widespread acceptance in global markets outside the United States, is a viable alternative to the withdrawable designs.
Tags : 
fixed circuit breaker, withdrawable circuit breaker, medium voltage, switchgear, arc flash, air insulated switchgear, gas insulated switchgear, ansi
    
Schneider Electric
Published By: Schneider Electric     Published Date: Feb 26, 2018
This on demand webinar contrasts the features of medium voltage fixed circuit breaker switchgear (FCBS) and existing withdrawable circuit breaker switgear (WCBS) designs. Modern FCBS design elements that are discussed include an internal disconnect for isolation and grounding of circuits and interlocked operation among disconnect, breaker, and grounding switch for improved safety. Furthermore, features such as lower maintenance, smaller footprint, and reduced life cycle costs that result from its simpler design will be explored. By comparing the traditional ANSI WCBS technology to that of the FCBS, this paper will demonstrate that the fixed design, which has gained widespread acceptance in global markets outside the United States, is a viable alternative to the withdrawable designs.
Tags : 
fixed circuit breaker, withdrawable circuit breaker, medium voltage, switchgear, arc flash, air insulated switchgear, gas insulated switchgear, ansi
    
Schneider Electric
Published By: Schneider Electric     Published Date: Sep 19, 2017
Are you facing the difficult decision to maintain or replace your aging switchgear? Upgrading can optimize your existing equipment and your budget. Learn your options and their benefits in our free white paper.
Tags : 
switchgear modernization, mv circuit breakers, lv circuit breakers, switchgear upgrades, electrical distribution equipment, schneider electric
    
Schneider Electric
Published By: Schneider Electric     Published Date: Sep 19, 2017
When your power system has aging switchgear, you need to work harder to maintain safety and reliability. But easy-to-install options are available to upgrade aging switchgear to bring safety and reliability up to modern standards. Find out how switchgear modernization works in the comprehensive "Answer Guide: Make Aging Switchgear Last Longer and Perform Better." The guide includes information like the 4 Big Wins of Modernization, embedded demonstration videos, an FAQ on how to modernize and links to other modernization resources.
Tags : 
switchgear modernization, mv circuit breakers, lv circuit breakers, switchgear upgrades, electrical distribution equipment, schneider electric, circuit breaker upgrade, obsolete switchgear
    
Schneider Electric
Published By: Schneider Electric     Published Date: Mar 03, 2017
Are you facing the difficult decision to maintain or replace your aging switchgear? Upgrading can optimize your existing equipment and your budget. Learn your options and their benefits in our free white paper.
Tags : 
switchgear modernization, mv circuit breakers, lv circuit breakers, switchgear upgrades, electrical distribution equipment, schneider electric
    
Schneider Electric
Published By: Schneider Electric     Published Date: Mar 03, 2017
Don't risk unplanned downtime at your facility. Discover 10 best practices that will help you maximize the life and reliability of your switchgear. Read our free white paper.
Tags : 
switchgear modernization, mv circuit breakers, lv circuit breakers, switchgear upgrades, electrical distribution equipment, schneider electric
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 06, 2017
If not, you are increasing the risk for costly, unplanned downtime. However, despite the importance of having a reliable flow of electricity, over half of building owners rely on reactive maintenance programs to care for their equipment. This means they wait until equipment fails completely before initiating corrective action, which is typically 3-4 times more costly than taking preventive measures. A good first step to go from being reactive to proactive is having a power system assessment performed to determine the current state and reliability of your electrical system. For more information on Power System Assessments, download our white paper, "Assessing the Health of a Facility's Electrical Power Distribution System".
Tags : 
electrical engineering services, electrical reliability, electrical risk assessment, power system assessment, risk assessment
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 06, 2017
Could you do more for worker safety? Protective gear alone can't prevent arc flash injury. In fact, according to NFPA 70E, injuries sustained during an arc ?ash event would be reduced and survivable due to arc-rated PPE. Complying with the safe work practices required by NFPA 70E and implementing arc flash mitigation strategies through engineering controls will enhance workplace safety for employees and lower financial risk for your company. Read the white paper, "Mitigating Arc Flash Hazards", for more information.
Tags : 
arc flash, nfpa 70e compliance, electrical workplace safety, arc flash risk assessment, arc flash analysis, arc flash mitigation solutions
    
Schneider Electric
Published By: Schneider Electric     Published Date: Nov 21, 2017
Could you do more for worker safety? Protective gear alone can't prevent arc flash injury. In fact, according to NFPA 70E, injuries sustained during an arc ?ash event would be reduced and survivable due to arc-rated PPE. Complying with the safe work practices required by NFPA 70E and implementing arc flash mitigation strategies through engineering controls will enhance workplace safety for employees and lower financial risk for your company. Read the white paper, "Mitigating Arc Flash Hazards", for more information.
Tags : 
arc flash, nfpa 70e compliance, electrical workplace safety, arc flash risk assessment, arc flash analysis, arc flash mitigation solutions
    
Schneider Electric
Published By: Schneider Electric     Published Date: Nov 21, 2017
If not, you are increasing the risk for costly, unplanned downtime. However, despite the importance of having a reliable flow of electricity, over half of building owners rely on reactive maintenance programs to care for their equipment. This means they wait until equipment fails completely before initiating corrective action, which is typically 3-4 times more costly than taking preventive measures. A good first step to go from being reactive to proactive is having a power system assessment performed. While often deemed expensive or unnecessary, the truth is power system assessments reveal opportunities to modernize, imiprove performance and help protect employees. To learn more, download our checklist, ""Ten Ways a Power System Assessment Can Save You Money""."
Tags : 
reliable power system, electrical assets, power system assessment, modernization, electrical workplace safety
    
Schneider Electric